3. Optionally, verify that the address was correctly set by entering the
4. Record the IP address on the pull out tab provided for this purpose on the port

Setting the switch date and time

The SAN48B-5 maintains the current date and time inside a battery-backed
real-time clock (RTC) circuit. The date and time settings are used for logging
events. Switch operation does not depend on the date and time; a switch with an
incorrect date and time value still functions properly. However, because the date
and time are used for logging, error detection, and troubleshooting, you should set
them correctly.
Complete the following steps to set the date and time of the switch.

Time zones

You can set the time zone for the switch by name. You can also set country, city or
time zone parameters.
If the time zone is not set with the new options, the switch retains the offset time
zone settings. The tsTimeZone command includes an option to revert to the prior
time zone format. For more information about the --old option, see the Fabric OS
Command Reference.
You can set the time zone for a switch using the tsTimeZone command. The
tsTimeZone command allows you to perform the following tasks:
v Display all of the time zones supported in the firmware
v Set the time zone based on a country and city combination or based on a time
The time zone setting has the following characteristics:
v You can view the time zone settings. However, only those with administrative
v The tsTimeZone setting automatically adjusts for Daylight Savings Time.
v Changing the time zone on a switch updates the local time zone setup and is
v By default, all switches are in the GMT time zone (0,0). If all switches in a fabric
v System services that have already started will reflect the time zone changes only
v Time zone settings persist across failover for high availability.
For more detailed information about the parameters of the tsTimeZone command,
refer to the Fabric OS Command Reference.
16
SAN48B-5 Installation, Service, and User Guide
switch:admin> ipaddrset
Ethernet IP Address [192.168.74.102]:
Ethernet Subnetmask [255.255.255.0]:
Gateway IP Address [192.168.74.1]:
DHCP [Off]: off
If you are going to use an IPv6 address, enter the network information in
semicolon-separated notation as a standalone command.
switch:admin> ipaddrset -ipv6 --add 1080::8:800:200C:417A/64
IP address is being changed...Done.
ipAddrShow command at the prompt.
side of the switch.
zone ID such as PST
permissions can set the time zones.
reflected in local time calculations.
are in one time zone, it is possible for you to keep the time zone setup at the
default setting.
after the next reboot.