Technical Data - BMW i wallbox Installation Instructions Manual

Table of Contents

Advertisement

Technical data

Electrical data
Cable supply:
Connection cross-section:
Supply terminals:
Temperature rating of supply terminals:
Rated current (configurable connection values):
Mains voltage:
Mains frequency:
System configuration:
Overvoltage category:
Design short-time withstand current:
Fusing (in the building installation):
DC fault current monitor:
Surface-mounted or mounted in wall
Minimum cross-section (depending on the cable
and type of installation):
- 5 x 2.5 mm² (16A rated current)
- 5 x 6.0 mm² (32A rated current)
Connection cable:
- Rigid (min.-max.): 0.2 – 16 mm²
- Flexible (min.-max.): 0.2 – 16 mm²
- AWG (min.-max.): 24 – 6
- Flexible (min.-max.) with wire-end ferrule
without / with plastic sheath:
0.25 – 10 / 0.25 – 10 mm²
105°C
10A, 13A, 16A, 20A, 25A or 32A
3-phase or 1-phase
230V
230/400V 3N~
50Hz / 60Hz
TT / TN / IT
III to EN 60664
< 10kA effective value to EN 61439-1
The fusing must comply with the local
regulations depending on the socket/cable
version (see rating plate).
≤ 6mA DC (integral)
35