Inserting the supply cable

General information

Use a suitable cable sheath diameter on the supply cable or increase the cable sheath diameter
using suitable sealing adapters.
Insert the supply cable a sufficient way into the cable gland or double membrane seal. The cable
sheath must be visible in the connection zone.
The installation duct or empty ductwork with the supply cable must not be screwed into the cable
gland or fed through the double membrane seal.
The supply cable must be routed in a straight line not exceeding the bending radii (approximate
cable diameter times 10) through the cable gland or double membrane seal.
The cable gland or double membrane seal must be installed correctly and adequately secured.
22
Installation on cavity walls
For installation on cavity walls, at least two
fastening screws, for example 1 and 2, must be
fastened to a solid element in the wall.
Special cavity wall plugs must be used for the
other fastening screws.
Note
For installation on cavity walls, it must be
ensured that the structure has an adequate
load-bearing capacity. 