INSTALLATION
Installation requirements
Comply with the installation regulations.
The electrical connection (supply cable) must be prepared.
Acclimatisation
If there is a temperature difference of more than 15°C between the means of transport and
installation site, the Wallbox must be allowed to acclimatise for at least two hours before it is
opened.
Opening the Wallbox immediately may cause condensation to form inside it and thus damage the
device when it is switched on. The device may also suffered damage in certain circumstances at a
later time after the installation.
Ideally the Wallbox should be stored for a few hours at the installation site before being installed.
If this is not possible, the Wallbox should not be stored outdoors or in a vehicle over night in low
temperatures (< 5°C).
List of tools
The following tools will be required for the installation work:
Slot head screwdriver for the supply terminals, blade width 5.5 mm
Cross head screwdriver PH2
Torx screwdriver T40
Removing the housing cover
16
Interlocks
1. Press the two interlocks 1 for the housing
cover on the underside of the Wallbox
upwards.
The housing cover should then jump out
slightly at the bottom.