INSTALLATION

Note
As delivered, the maximum charging current for the Wallbox is set to 32 A.

Prerequisites for installation

Comply with the locally applicable installation guidelines.
The electrical connection (NEMA 6-50p socket) must be prepared.
Acclimatization: If the temperature difference between transportation and installation location
is greater than 15 °C, then the Wallbox should be allowed to acclimatize for at least two hours
without being opened.
Under some circumstances, damage from condensate water may not arise until at some point
after the installation.
Ideally, the Wallbox should be left at the installation location for a few hours in advance. If this is
not possible, then the Wallbox should not be stored overnight in the open air or in a vehicle at low
temperatures (< 5 °C).
List of tools
The following tools are needed for the installation:
Torx screwdriver T40

Recommended installation positions

When selecting the installation position, please take into account the position of the charging
connection on your vehicle and the usual direction of parking. Examples:
BMW i3
1 Recommended installation position
2 Alternative installation position
16