Download Print this page

Troubleshooting For Motors And Sensors - Epson Stylus Photo RX585 Service Manual

Hide thumbs Also See for Stylus Photo RX585:

Advertisement

EPSON Stylus Photo RX585/RX595/RX610
Carriage operates but error indicated
Table 3-19. Carriage operates but error indicated
Cause
Check Point
Upper case of scanner is
Upper case of scanner is
removed.
removed.?
Defective main board
---
LED does not light up
Table 3-20. LED does not light up
Cause
Check Point
Connector on the Main
Connector CN19 on main
Board is disconnected
board is disconnected?
Does the lamp light up when
Defective CIS Unit
the CIS Unit is replaced?
Defective main board
---
Picture cannot be read clearly
Table 3-21. Picture cannot be read clearly
Cause
Check Point
Is the document table (glass)
Soiled document table
free from dirt and wiping
mark?
Defective CIS Unit
---
Defective main board
---
Troubleshooting
Yes/No
Remedy
Yes
Install the upper case.
---
Replace the main board
Yes/No
Remedy
Connect the connector
Yes
CN19 on the main board.
Yes
Replace the CIS Unit.
---
Replace the main board
Yes/No
Remedy
No
Clean the document table.
---
Replace the CIS Unit.
---
Replace the main board
Troubleshooting When There is No Error Display

3.3.6 Troubleshooting for Motors and Sensors

Motor
Table 3-22. Motor Resistance and Check Points
Motor Name
Location
CR motor
CN14 (White)
PF motor
CN13 (Black)
CR motor (Scanner Unit)
CN17 (White)
Sensor
Table 3-23. Sensor Check
Sensor Name
Location
PE sensor
CN6 Pin 1&3
(3.3V DC ±5% )
APG sensor
CN7 Pin 1&3
(3.3V DC ±5% )
CD-R Guide sensor
CN4 Pin 1&2
(3.3V DC ±5% )
CD-R Tray sensor
CN4 Pin 3&4
(3.3V DC ±5% )
CN3 (Panel Board)
Case Open Sensor
(3.3V DC ±5% )
Pin 3&4
Note :
Refer to "2.1.2 Motors and Sensors" (p.35)
Revision B
Check Point
Resistance
22.7 Ω ± 10%
Pin 1 & 2
21.2 Ω ± 10%
Pin 1 & 2
Pin 1 & 2
Signal Level
Sensor Status
2.4V or over
Paper absent
Less than 0.4V
Paper present
2.4V or over
PG position
Less than 0.4V
Out of PG position
Open: 2.4V or over
CD-R Guide down
Close: Less than 0.4V
CD-R Guide up
Open: 2.4V or over
CD-R Tray present
Close: Less than 0.4V
CD-R Tray absent
Open: 2.4V or over
Scanner Unit open
Close: Less than 0.4V
Scanner Unit closed
for the locations of the motors and sensors.
58

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Stylus photo rx595Stylus photo rx610