Tree MRB 500g Operation Manual

Tree MRB 500g Operation Manual

Mid resolution

Advertisement

MRB Series Mid Resolution Balances
Compact Scales
Weighing Equipment
MRB 500g
MRB 1200g
MRB 2500g
MRB 6000g
MRB 10000g
Operation Manual
Professional

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MRB 500g and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tree MRB 500g

  • Page 1 Professional Weighing Equipment MRB Series Mid Resolution Balances Compact Scales MRB 500g MRB 1200g MRB 2500g MRB 6000g MRB 10000g Operation Manual...
  • Page 2: Table Of Contents

    Table of Contents Section Page Declaration of Conformity Customer Service Introduction Safety Weight Scale Functions Scale Description Application & Conformity Getting Started Delivery Assembly & Installation 10-11 Application Menu 11-12 Calibration 12-13 Maintenance & Service Transportation & Storage Warranty Rev 2, 1_19_2016...
  • Page 3: Declaration Of Conformity

    Declaration of conformity for apparatus with CE mark We hereby declare that the product to which this declaration refers conforms to the following standards. Electronic scale: MRB Compact Scales Models MRB 500g MRB 1200g MRB 2500g MRB 6000g MRB 10000g...
  • Page 4: Customer Service

    Introduction What you should know about this Operation Manual: Tree® Professional Weighing Equipment products are simple to operate. Nevertheless, you should read through these operating instructions in their entirety, so that you can make optimum use of the full potential of the weighing scale in your daily work activities.
  • Page 5: Safety

    Safety Representations & Symbols Note: Important instructions, which involve safety, are highlighted with the appropriate mark Safety recommendations When using the weighing equipment in surroundings with increased safety requirements, the corresponding regulations must be observed. The weighing scale may only be used with the power adapter supplied. Before connecting the power adapter to the scale, the user must ensure that the operating voltage stated on the power adapter is compliant with the mains voltage.
  • Page 6: Weight Scale

    Weight Scale Construction & Functions The weighing scale consists of the following parts;  The Scale body (1)  Scale pan (2)  The adapter  Operation manual Rev 2, 1_19_2016...
  • Page 7: Functions

    Functions Technical Data Weighing pan Model number Capacity Division Size MRB 500 500 g 0.1 g 175 x 160 mm MRB 1200 1200 g 0.1 g 175 x 160 mm MRB 2500 2500 g 0.1 g 175 x 160 mm MRB 6000 6000 g 175 x 160 mm...
  • Page 8: Scale Description

    Scale Description Weighing platform Battery Compartment Cover Battery Compartment Batteries 6 AA (Not included AC adapter socket Weighing Units Stable Indicator Zero Indicator Tare Indicator Low Battery Rev 2, 1_19_2016...
  • Page 9: Application & Conformity

    Application & Conformity The Following are instructions of how to correctly use the weight scale: The weighing scale may only be used for the weighing of solid-materials and of liquids filled into secure containers. The maximum capacity load of the weighing scale must never be exceeded, otherwise the weighing scale may be damaged.
  • Page 10: Delivery

     Unpack the scale carefully.  When outside temperatures are very low, the scale should be stored for a couple hours and kept in its box in a dry room at normal temperature, so that no condensation settles on the unit when opening the box. ...
  • Page 11: Application Menu

    The Scale should only be connected to the mains voltage socket with the power adapter supplied. Check before connecting the power adapter to the mains socket, that the operating voltage stated on the power adapter complies with the local mains voltage. If the operating voltage is not the same as the mains voltage, the power adapter must not be connected to the mains socket and contact customer service.
  • Page 12: Calibration

     UNIT KEY is used to toggle between different weighing units. Clearing tare weight  Place an empty container on the platter. Press the TARE key. The WEIGHT display shows 0.000. When the container is removed from the platter, the WEIGHT display will show a minus (-) value which is the weight of the container Clearing previous tare value Remove the weight from the platter then press the TARE key so that the TARE indicator...
  • Page 13: Maintenance & Service

    NOTE: X is the calibration weight which can be set according to your requirements. The weight needed when re-calibrating your Tree scale needs to be at least half (1/2) of the capacity of the scale with two thirds (2/3) being ideal as this will give you the most accurate reading.
  • Page 14: Transportation & Storage

    Transportation & Storage Your weighing machine is a precision instrument, treat it carefully. Avoid shaking, severe impacts and vibration during the transportation. Make sure that there are no marked temperature fluctuations during the transportation and that the weighing machine does not become damp (condensation). If you would like to take the weighing machine out of service for an extended period, disconnect it from the electricity supply, clean it thoroughly (refer to Maintenance &...

This manual is also suitable for:

Mrb 2500gMrb 1200gMrb 6000gMrb 10000g

Table of Contents