FUNCTION SETTINGS
1. Enter function setting mode.
Press [ON/OFF] to turn the power off, Press [ZERO] first, then press
[ON/OFF], while keeping [ZERO] pressed, the display will show A_ON
or A_OFF.
2. Selection of auto backlight mode.
When the balance enter function setting menu. Press [UNIT] key, the
display will show L_ON or L_OFF, press [ZERO], selection display
L_ON, this means auto backlight function is active, press [ZERO]
again, the display will show L_OFF, this means auto backlight function
is inactive, i.e. shut off backlight function.
3. Selection of auto shut off mode.
When the balance enter function setting menu. Press [UNIT] key, the
display will show A_ON or A_OFF, press [ZERO], selection display
A_ON, this means auto shut off function is active. Press [ZERO] again,
the display will show A_OFF, this means auto shut off function is
inactive.
4. Return to weighing mode.
Press [ON/OFF] to turn the power off, press [ON/OFF] again to turn on
the power and the scale return to the weighing mode.
COMPACT SCALE
INSTRUCTION MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KRH-3000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tree KRH-3000

  • Page 1 COMPACT SCALE FUNCTION SETTINGS 1. Enter function setting mode. Press [ON/OFF] to turn the power off, Press [ZERO] first, then press [ON/OFF], while keeping [ZERO] pressed, the display will show A_ON INSTRUCTION MANUAL or A_OFF. 2. Selection of auto backlight mode. When the balance enter function setting menu.
  • Page 2: Safety Precautions

    SAFETY PRECAUTIONS SPECIFICATIONS All safety messages are identified by the words "WARNING" and Model number Capacity Division "CAUTION". These words mean the following: KRH-3000 3000 g 0.1g KMR-6000 6000g WARNING Important information to alert you to a situation that might cause serious injury...
  • Page 3: When To Calibrate

    calibration weight. Place the shown weight on the platform. ●  Low battery indication kg/g/lb/lb:oz/oz conversion 4. Wait for the stable indicator to be displayed then press [UNIT] key, the display will return to A/D value. Take off calibration weight then turn off ●...
  • Page 4 DISPLAY Display Weighing unit ON/OFF key Turns the scale ZERO indicator Power on/off. Indicates when the scale UNIT key zero is correct. Changes weighing units TARE key Substracts the weight of a container ZERO key Sets display to zero Low battery indicator BOTTOM PREPARATION Battery compartment cover...
  • Page 5: Setting Up The Scale

    Whenever possible, please allow the balance to warm up for 10 minutes R6P/LR6/AA size after first turning to power on, so that the balance will function properly and Dry batteries. accurately. Battery compartment (batteries are not included) Error messages Err-0: Overload AC adapter (selectable) Plug the AC adapter to the AC...