Post Error Indicators; Post Errors Message Definition; Post Related Troubleshooting - HP proliant DL160SE G6 Maintenance And Service Manual

Hide thumbs Also See for proliant DL160SE G6:
Table of Contents

Advertisement

POST error indicators

When POST detects a system failure, it displays a POST error message.

POST errors Message Definition

When a non-fatal error occurs during POST, the screen will display an error message with the format
"xxx-Error Identifier String" where "xxx" is a unique number code that matches ODM system specific
error documentation and may be a hexadecimal or decimal value.
All Error messages describe the problems as shown below:
Table 19 POST Error Messages
Error code
601
605
611
612
613
624
622
194
192
197
005
041
040
048
003
701
702
120
122

POST related troubleshooting

Perform the following procedures when POST fails to run, displays error messages.
Description
Error: BMC Not Responding
BMC Has Detected Fatal Hardware Error
Internal User Area Of BMC FRU Corrupted
Controller Update 'boot block' Firmware Corrupted
Controller Operational Firmware Corrupted
Power Supply Failure or Power Supply Unplugged
Either Fan Failure or Fan Missing
CPUID, Processor family are different
L3 cache size mismatch
Processor speeds mismatched
CMOS Checksum Bad
Display memory test failed
Refresh timer test failed
Password check failed
CMOS Battery Low
Insufficient Runtime space for MPS data.!!.
System may operate in PIC or Non-MPS mode.
No enough APIC ID in range 0-0Fh can be assigned to IO APICs.
(Re-assigning CPUs' local APIC ID may solve this issue)
MPS Table is not built! System may operate in PIC or Non-MPS mode.
$A0CCMOS Cleared by Jumper. Restore the Jumper and Continue...
$A0CPassword Cleared By Jumper. Restore the Jumper and Continue...
Diagnostic tools and setup utilities 110

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents