Allen-Bradley SLC 500 Manual page 175

Hide thumbs Also See for SLC 500:
Table of Contents

Advertisement

Format: nnaaaaa.bb[_dd][\p]
nn is the name or type of the variable
aaaaa is the address of the variable (addresses are in octal)
.bb is the bit number of the variable
_dd is the destination address
\p is an optional protocol or port number (range 1-2)
Device
Address
Data
Prefix
Range
Range
Min.
32 bit
VD (2)
0-17777
-1E+08 1E+08
VD (2)
40000-41237
-1E+08 1E+08
VL (2)
0-17777
-1E+08 1E+08
VL (2)
40000-41237
-1E+08 1E+08
VF
0-17777
-1E+08 1E+08
VF
40000-41237
-1E+08 1E+08
VR
0-17777
-1E+08 1E+08
VR
40000-41237
-1E+08 1E+08
Words
V (2)
0-377
-32768
V (2)
400-777
-32768
V (2)
1000-1377
-32768
V (2)
1400-7377
-32768
V (2)
7400-7777
-32768
V (2)
10000-37777
-32768
V (2)
40000-40177
-32768
V (2)
40200-40377
-32768
V (2)
40400-40477
-32768
V (2)
40500-40577
-32768
V (2)
40600-40777
-32768
V (2)
41000-41077
-32768
V (2)
41100-41117
-32768
V (2)
41140-41157
-32768
V (2)
41200-41237
-32768
Bits
GX
0-3777
0
GY
0-3777
0
X
0-1777
0
Y
0-1777
0
C
0-3777
0
S
0-1777
0
T
0-377
0
CT
0-377
0
SP
0-777
0
Note: To specify bits for V, use the form Vaaa.bb, where aaa means the word address and bb means
the bit specification from 00-15. Writing to bits cause a word write.
Note 1:V locations can be interpreted as Signed Integer, Unsigned Integer, or BCD. The normal
interpretation of a V location is Signed Integer. Reading V locations in a different format is done by
adding a colon and a suffix to the V location address.
V100:C Read or Write the contents of V100 as BCD 0000-9999
V100:I Read or Write the contents of V100 as Signed Integer -32767 to 32767
V100:U Read or Write the contents of V100 as an Unsigned Integer 0 to 65535
206 • • • • Siemens
Data
Data
Data
Data
Bit
Range
Format Width Word
write
Max.
Order (y/n/rmw)
S (1)
32
norm
n/a
S (1)
32
norm
n/a
S (1)
32
rev.
n/a
S (1)
32
rev.
n/a
D
32
norm
n/a
D
32
norm
n/a
D
32
rev.
n/a
D
32
rev.
n/a
32767
S (1)
16
n/a
ww (4)
32767
S (1)
16
n/a
ww (4)
32767
S (1)
16
n/a
ww (4)
32767
S (1)
16
n/a
ww (4)
32767
S (1)
16
n/a
ww (4)
32767
S (1)
16
n/a
ww (4)
32767
S (1)
16
n/a
ww (4)
32767
S (1)
16
n/a
ww (4)
32767
S (1)
16
n/a
ww (4)
32767
S (1)
16
n/a
ww (4)
32767
S (1)
16
n/a
ww (4)
32767
S (1)
16
n/a
ww (4)
32767
S (1)
16
n/a
ww (4)
32767
S (1)
16
n/a
ww (4)
32767
S (1)
16
n/a
n
1
n/a
1
n/a
ww (4)
1
n/a
1
n/a
ww (4)
1
n/a
1
n/a
ww (4)
1
n/a
1
n/a
ww (4)
1
n/a
1
n/a
rmw
1
n/a
1
n/a
ww (4)
1
n/a
1
n/a
ww (4)
1
n/a
1
n/a
ww (4)
1
n/a
1
n/a
n
Read Description
/ Write
& Notes
R/W Variable double
R/W Variable double
R/W Variable long
R/W Variable long
R/W Variable float
R/W Variable float
R/W Variable real
R/W Variable real
R/W Timer Accumulator
R/W (System Status )
R/W Counter Accumulator
R/W User ( Variable)
R/W (System Status)
R/W Variable
R/W GX (Global Input)
R/W
GY (Global Output)
R/W
"X" (Input)
R/W
"Y" (Output)
R/W
"C" (Variable)
R/W
"S" (Stage Status)
R/W
"TMR Status"
R/W
"CNT Status"
R
"Spec.Relay" (System Status) (3)
R/W Global Input (Bit)
R/W Global Output (Bit)
R/W Input (Bit)
R/W Output (Bit)
R/W Variable (Bit)
R/W Stage Status (Bit)
R/W Timer Status (Bit)
R/W Counter Status (Bit)
R
System Status (Bit)
QUICKDESIGNER

Advertisement