Error #: 02:A5
Error Msg ERROR 02:A5 There was more then 10k words to allocate for the Rx table
Explanation: The Quick Panel can only dynamically allocate 10 thousand WORDs or 20 thousands
bytes for the Rx table. To many local registers have been created.
Error #: 02:A6
Error Msg ERROR 02:A6 The packet received was to large
Explanation: A packet was received which was larger then the Receive Buffer. The End of Packet
character may be incorrect.
Error #: 02:A7
Error Msg ERROR 02:A7 The communication timed-out
Explanation: The Communications timed-out wait for a packet.
Error #: 02:A8
Error Msg ERROR 02:A8 Packet to large on the Receive of a Solicited Cmd\0" },
Explanation: While executing a Receive Command in a Solicited Sequence a packet was received
which was larger then the Receive Buffer. The End of Packet character may be incorrect.
Error #: 02:A9
Error Msg ERROR 02:A9 Comm time-out on the Receive of a Solicited Cmd\0" },
Explanation: While executing a Receive Command in a Solicited Sequence the communications
timed-out.
Error #: 02:AA
Error Msg ERROR 02:AA Transmitter time-out waiting for an XON char or the DSR line
Explanation: The transmitter in the Quick Panel could not send out any characters because it was
waiting for a XON character from the controller or the DSR line to the controller was not active.
Error #: 02:AB
Error Msg ERROR 02:AB Recv failed, then proc as Unsol Seq, then Recv timeout getting CMD
Explanation: A Sequence was executing a Receive Command, the data received did not match what
was intended. The data received from the controller was then processed as an Unsolicited Sequences.
Then the receiver timed-out waiting for the intended data from the controller. The data received from
the controller may not be an Unsolicited Command. The Receive Command in the Sequence may not
be correct, thus the Quick Panel would not receive another command from the controller.
Error #: 02:AC
Error Msg ERROR 02:AC Recv failed, then proc as Unsol Seq, then Recv Err buffer overflow
Explanation: A Sequence was executing a Receive Command, the data received did not match what
was intended. The data received from the controller was then processed as an Unsolicited Sequences.
Then the receive buffer over flowed getting the intended data from the controller. The End of Packet
character may be incorrect.
Error #: 02:AD
Error Msg ERROR 02:AD Compiler version does not match the Driver Version\0"}
Explanation: The Compiler and the Driver have been given a version numbers which should match.
The version numbers are used to make sure that the Compiler and Driver work together. If the Version
numbers are different it could cause unexpected results. This error indicates that Version numbers do
not match.