Troubleshooting

Before You Begin
1. Make sure that the battery is charged. Recheck
the battery after several minutes to make sure the
battery is holding its charge.
Problem
Tool is inoperative.
Motor is inoperative.
Motor runs but tool will not
complete a cycle.
Dies stop during operation.
LED glows for 20 seconds.
Tool loses oil.
Note: For Warranty Service or Repair, contact Greenlee customer service at 800-435-0786.
4455 Boeing Drive • Rockford, IL 61109-2988 • USA • 815-397-7070
An ISO 9001 Company •
Greenlee Textron Inc. is a subsidiary of Textron Inc.
www.greenlee.com
E12CCXL 12-ton Battery-powered Tool
Possible Cause
Dirt, contaminants, etc., in ram area
of tool.
Tool battery contacts damaged.
Tool components worn or damaged.
Low or uncharged battery.
Broken switch components.
Oil level low.
Air in hydraulic system.
Cold oil.
Oil level low.
Air in hydraulic system.
Battery charge low.
Damaged internal seal.
USA Tel: 800-435-0786
Fax: 800-451-2632
2. Use a nonflammable contact cleaner or pencil
eraser to clean the electrical contacts on the battery
and tool.
3. Reinstall the battery and check the tool again.
Probable Remedy
Clean tool.
Reform contacts.
Return tool to a Greenlee Authorized
Service Center.
Try known charged battery. Inoperative
battery may be discharged or may have
reached life expectancy.
Return tool to a Greenlee Authorized
Service Center.
Return tool to a Greenlee Authorized
Service Center.
Pull trigger and hold retract button
simultaneously. Run for approximately
10 seconds, and then attempt to
crimp. If unsuccessful, return tool to a
Greenlee Authorized Service Center.
Pull trigger and hold retract button
simultaneously to warm oil. Store tool
in warm area.
Return tool to a Greenlee Authorized
Service Center.
Pull trigger and hold retract button
simultaneously. Hold for approximately
10 seconds.
Charge or replace battery.
Return tool to a Greenlee Authorized
Service Center.
Canada Tel: 800-435-0786