Example: Counter Start Source = OFF

The counter starts on the counterReset Cmd.
The counter continues unless a new counterReset Cmd is received, which then restarts the
counter at 00.
When Counter Reset Source= 'Event' or 'CounterEnd' the counter is reset to 00 but does
not restart counting, until the next CounterReset Cmd.

Example: Counter Start Source = CounterEnd (itself)

Counter starts when Counter Mode is set to Active.
A Counter Reset CMD will reset the counter to 00 and it then continues counting.
counterResetSource must be set to CounterEnd. When the counterValue feature reaches
the counterDuration value an event is generated and the counter is reset to 00, then continues.
Genie_TS_Series GigE Vision Camera