Teledyne TS-M4096 User Manual page 70

Genie ts series
Table of Contents

Advertisement

Line Status All
Line Inverter
Input Line Detection Level
Threshold for TTL
Threshold for 12V
Threshold for 24V
Input Line Debouncing
Period
Output Line Source
Off
Software Controlled
Pulse on: Start of Frame
Pulse on: Start of Exposure
Pulse on: End of Exposure
Pulse on: Start of Readout
Pulse on: End of Readout
Pulse on: Valid Frame
Trigger
Pulse on: Invalid Frame
Trigger
Pulse on: Start of Acquisition
Pulse on: End of Acquisition
Pulse on: End of Timer 1
Pulse on: End of Counter 1
Pulse on: Input 1 Event
Pulse on: Input 2 Event
Pulse on: Input 3 Event
Pulse on: Input 4 Event
Pulse on: Software
Command
Output Line Pulse Signal
Activation
Rising Edge
68  Operational Reference
LineStatusAll
LineInverter
False / True
lineDetectionLevel
Threshold_for_TTL
Threshold_for_12V
Threshold_for_24V
lineDebouncingPeriod
outputLineSource
SoftwareControlled
PulseOnStartofFrame
PulseOnStartofExposure
PulseOnEndofExposure
PulseOnStartofReadout
PulseOnEndofReadout
PulseOnValidFrameTrigger
PulseOnInvalidFrameTrigger
PulseOnStartofAcquisition
PulseOnEndofAcquisition
PulseOnEndofTimer1
PulseOnEndofCounter1
PulseOnInput1
PulseOnInput2
PulseOnInput3
PulseOnInput4
PulseOnSoftwareCmd
outputLinePulseActivation
RisingEdge
Returns the current status of all available line
signals, at time of polling, in a single bitfield. The
order is Line1, Line2, Line3, ... (RO)
Controls whether to invert the polarity of the
selected input or output line signal.
Specifies the voltage threshold required to
recognize a signal transition on an input line.
A signal below 0.8V will be detected as a Logical
LOW and a signal greater then 2.4V will be
detected as a Logical HIGH on the selected input
line.
A signal below 2.0V will be detected as a Logical
LOW and a signal greater then 10V will be detected
as a Logical HIGH on the selected input line.
A signal below 4.0V will be detected as a Logical
LOW and a signal greater then 20V will be detected
as a Logical HIGH on the selected input line.
Specifies the minimum delay before an input line
voltage transition is recognizing as a signal
transition.
Selects which internal signal or event driven pulse
or software control state to output on the selected
line. Note, the LineMode feature must be set to
Output. The List of supported output line sources is
product-specific. The
Event Control section
provides details and timing diagrams for the
supported trigger modes.
Off
Line output is Open
The OutputLineValue feature changes the state of
the output
Generate a pulse on the start of the Frame Active
event
Generate a pulse on the ExposureStart event. This
option is typically used to trigger a strobe light.
Generate a pulse on the ExposureEnd event. This
option is typically used to trigger a strobe light.
Generate a pulse on the ReadoutStart event.
Generate a pulse on the ReadoutEnd event.
Generate a pulse on the ValidFrameTrigger event.
Generate a pulse on the InvalidFrameTrigger
event.
Generate a pulse when the AcquisiontStart event
occurs
Generate a pulse when the AcquisiontStop event
occurs
Generate a pulse on the TimerEnd 1 event.
Generate a pulse on the CounterEnd 1 event.
Generate a pulse on the Input signal 1 event
Generate a pulse on the Input signal 2 event
Generate a pulse on the Input signal 3 event
Generate a pulse on the Input signal 4 event
Generate a pulse on the Input of a Software
Command
Specifies the input line activation mode to trigger
the OutputLine pulse.
Specifies that the trigger is considered valid on the
rising edge of the source signal.
Genie_TS_Series GigE Vision Camera
1.00
Expert
1.00
Beginner
1.00
Beginner
DFNC
1.00
Beginner
DFNC
1.00
Beginner
DFNC
1.00
Beginner
DFNC

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ts-m3500Ts-c3500Ts-m2500Ts-c2500Ts-c4096

Table of Contents