1. Outline
This manual provides the specifications, part names and I/O interfaces for A1SD71-S7
positioning module (hereinafter referred to as A1SD71).
After unpacking A1SD71, confirm that all products shown below are included.
A1SD71-S7 positioning module
External wiring connector
(Model)
Connector
Connector cover
FUJITSU COMPONENT LIMITED

2. Performance Specifications

The performance specifications of the A1SD71 are shown below.
Item
Number of I/O points
Number of control axes
Interpolation
Capacity
Positioning
Setting
data
method
RAM memory backup
Method
Positioning
units
Positioning
Positioning
speed
Product name
FCN-361J040-AU
FCN-360C040-B
48 points (number of occupied slots: 2)*
2 (simultaneous or independent)
Linear interpolation (for simultaneous 2 axes)
400 points pea axis
Input from A6GPP, A6PHP, A7PHP, A7HGP, A7LMS,
AD71TU or sequence program
15 minutes without battery (25 )
Lithium battery guarantees power failure backup for a
total of 300 days. Battery guaranteed for five years.
Absolute and/or incremental method.
Command method can be selected for each axis from
the following four types.
1 to 16,252,928 (pulse)
Max 162(m)
(command unit: 0.1 to 10 m/pulse)
Max 16200 (inch)
(command unit: 1
Max 16200 (degree)
(command unit: 1
Command method can be selected for each axis from
the following four types.
10 to 200000(pulse/sec) (command unit: 10 pulse/sec)
10 to 120000(mm/min) (command unit: 10 mm/min)
1 to 12000 (inch/min) (command unit: 1 inch/min)
1 to 12000 (degree/min) (command unit: 1 degree/min)
Quantity
Specifications
-5
10
to 0.001 inch/pulse)
-5
10
to 0.001 degree/pulse)
1
1

Advertisement