Basic Settings
Note: Before loading the configuration data from the ACA, the device
compares the password in the device with the password in the ACA

configuration data.

The device loads the configuration data if
the admin password matches or
there is no password saved locally or
the local password is the original default password or
no configuration is saved locally.
Status
Meaning
notPresent
No ACA present
ok
The configuration data from the ACA and the device
match.
removed
The ACA was removed after booting.
notInSync
- The configuration data of the ACA and the device do
not match or only one file exists
or
- no configuration file is present on the ACA or on the
device
outOfMemory
The local configuration data is too extensive to be
stored on the ACA.
wrongMachine
The configuration data in the ACA originates from a
different device type and cannot be read or converted.
checksumErr
The configuration data is damaged.
Table 3: ACA Status
a. In these cases, the ACA status is identical to the status "ACA not in
sync", which sends "Not OK" to the signal contacts, and the device
status.
b. In this case, the ACA status ("notInSync") deviates from the status
"ACA not in sync", which sends "OK" to the signal contacts, and the
device status.
RM Web L3E
Release 6.0 07/2010