Cisco IE 2000 Installation Manual page 60

Hide thumbs Also See for IE 2000:
Table of Contents

Advertisement

Figure 34 Inserting Wires into the Alarm Connector (Alarm Input Circuit)
1
2
1
IN1 - External device connection 1
5.
Use a ratcheting torque flathead screwdriver to tighten the alarm connector captive screw (above the installed wire
leads) to 2 in-lb (0.23 N-m). (See
Note:
Do not over-torque the power and alarm connectors' captive screws. Do not exceed 2 inch-lbs (0.23 N-m) torque.
Figure 35 Securing the Alarm Connector Captive Screws
6.
Repeat the above steps to insert the input and output wires of one additional external alarm device into the alarm
connector.
Figure 36 on page 61
shows the completed wiring for two external alarm devices. The first alarm device circuit is wired
as an alarm input circuit; the IN1 and REF connections complete the circuit. The second alarm device circuit is wired as
an alarm output circuit that works on a normally open contact basis; the NO and COM connections complete the circuit.
2
REF - External device connection 2
Figure 35 on page
60.)
60

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents