Troubleshooting - Stihl FSA 85 Instruction Manual

Hide thumbs Also See for FSA 85:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 30
English

Troubleshooting

Always remove the battery before carrying out any work on the power tool.
Condition
Machine does not start when switched on
Machine cuts out during operation
Running time is too short
Battery jams when being inserted in power
tool / charger
48
Cause
No electrical contact between power tool
and battery
Battery has low charge
(1 LED on battery flashes green)
Battery too hot / too cold
(1 LED on battery glows red)
Fault in battery
(4 LEDs on battery flash red)
Power tool too hot
(3 LEDs on battery glow red)
Electromagnetic problem or fault in
machine
(3 LEDs on battery flash red)
Moisture in power tool and/or battery
Battery or machine's electronics too hot Take battery out of machine, allow bat-
Electrical or electromagnetic malfunction Remove the battery and refit it
Battery not fully charged
Using unsuitable nylon line
Useful life of battery has been reached
or exceeded
Guides / contacts dirty
Remedy
Remove the battery, visually check con-
tacts and refit battery
Charge the battery
Allow battery to cool down / allow battery
to warm up slowly at temperature of
about 15°C - 20°C
Take the battery out of the power tool
and refit it. Switch on the machine – if the
LEDs continue to flash, the battery has a
malfunction and must be replaced.
Allow power tool to cool down
Take the battery out of the power tool
and refit it. Switch on the power tool – if
the LEDs still flash, the power tool has a
malfunction and must be checked by a
1)
servicing dealer
.
Allow power tool / battery to dry
tery and machine to cool down
Charge the battery
Replace nylon line
1)
Check battery
and replace
Carefully clean the guides / contacts
FSA 65, FSA 85

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fsa 65

Table of Contents