Hearth & Shelf Requirements
Visage & Elegant
figure 1
Hearth dimensions, Shelf clearance & Front dimensions

1. GAS CONSUMPTION

Natural gas appliances have a maximum
gas input at the high setting of 6.85kW(gross)
Propane gas appliances have a maximum gas
input at the high setting of 6.7kW (gross)

2. OPERATING THE FIRE

The Oxysafe flame sensing & flue blockage
safety system.
For your safety, this appliance is fitted with a
flue blockage safety device which will shut
down the appliance in the event of abnormal
flue conditions. This device is NOT a
substitute for an independently mounted
Carbon Monoxide detector.
The device will also automatically shut off the
gas supply to the fire if the pilot flame goes
out due to lack of oxygen or for any other
reason.
USERS INSTRUCTIONS
See item 5
on page 3
Page 5
Adorn
Icon
If this device starts to repeatedly shut off the
gas, get expert advice.
This device incorporates a probe which
senses that the heat from the pilot flame is
correct. If this probe is cool, the device will
prevent any gas flow unless the sliding control
button is held at the ignition position.
If, for any reason, the flames go out when the
fire is hot or if the fire is turned off when hot,
always wait at least three minutes before
attempting to relight.
To light the fire
The control is shown in figure 2.
1. Slide the control button to the bottom
(ignition) position marked
In this position, the electronic ignition system
should cause a series of sparks which should
light the pilot. Within four seconds of the pilot
igniting, the main burner should light at its
minimum setting.
If no sparks are produced to light the pilot, the
.