The Fireplace - Valor BR622 Installer's Manual

Hide thumbs Also See for BR622:
Table of Contents

Advertisement

3.1
Check Ignition Spark
Before attempting to install, it is worth
checking that the electronic ignition
system performs satisfactorily.
3.1.1 Fit the battery to the ignition block located
below the burner tray at the left side (see
figure 7). The positive (+) terminal is to
the right as you insert.
figure 7
Battery Fitting
3.1.2 Rotate the control pivot bracket clockwise
as far as it will go (see figure 8).
This should close the ignition circuit.
Sparks should be seen tracking from the
electrode pin to the thermocouple tip (see
figure 9).
If there are no sparks make the following
checks.
a)
Check condition of battery and that it is
correctly fitted.
b)
Check spark gap between electrode wire
and thermocouple tip (see figure 9).
c)
If a & b are satisfactory, check the ignition
circuit and components - see the servicing
section in this manual.
figure 8
Control pivot
rotation
figure 9
Pilot ignition
system
INSTALLER GUIDE
4.1
4.1.1 Fireplace size
4.1.2 Fireplace general condition
Page 9

4.THE FIREPLACE

INSTALLATIONS NOT REQUIRING
OPTIONAL SPACING KIT 617K
The fireplace must comply with the
requirements described in section 2.2.
This will probably entail removing the
fireback and infill material behind the
fireback. The debris catchment area
shown in figure 10 must be kept clear of
obstructions.
figure 10
Fireplace areas
The fireplace floor should be reasonably
flat to ensure that the convection box can
be installed without it rocking and so that
a good seal can be made at the bottom
front of the box. The front face of the
fireplace should be reasonably flat over
the area covered by the convection box
top and side flange seals to ensure good
sealing. These faces should be made good
if necessary. If the appliance is to be fitted
against a wall with combustible cladding,
the cladding must be removed from the
area covered by the fire front surround
(see figure 5). We suggest that the actual
fire front is used as a template to mark the
area for combustible cladding removal.