12.6 Disassembly and Replacement

[A] DEV. motor assembly
1. If a STP (KK-1600) is attached to the copier,
disconnect the power cable.
2. Detach the manual pocket.
3. Detach the toner cartridge and the process unit.
4. Detach rear cover. (See Fig. 2-6-1)
5. Remove MAIN PWA.
(See Fig. 2-6-25 and 2-6-26)
6. Detach the connectors from RELAY PWA
(CN32/CN39/CN54) and release the clamp.
7. If an ADU (MD-0101) is attached to the copier,
open it.
8. Open side cover.
9. Open front cover.
10. Remove 3 screws and remove DEV. motor as-
sembly.
e-STUDIO160/200/250 DEVELOPER UNIT
083
DEV. motor assembly
Screw
White
Black
Blue or Red
12 - 8
CN39
Fig. 12-6-1
Front cover
Fig. 12-6-2
Fig. 12-6-3
December 2002 TOSHIBA TEC
RELAY PWA
CN32
CN54
Clamp
082
Side cover
Screw
Screw
084