Debugging And Verification Using Show Commands - Brocade Communications Systems ICX 7450 Deployment Manual

Hide thumbs Also See for ICX 7450:
Table of Contents

Advertisement

UNIT 9:
ICX7750-32Q Router(config)#stack unit 1
ICX7750-32Q Router(config-unit-1)#stack suggested-id 9
ICX7750-32Q Router(config-unit-1)#stack enable
Enable stacking. This unit actively participates in stacking
stacking is enable. optical monitoring for stacking ports 1/2/1, 1/2/4 is not
available.
UNIT 10:
ICX7750-32Q Router(config)#stack unit 1
ICX7750-32Q Router(config-unit-1)#stack suggested-id 10
ICX7750-32Q Router(config-unit-1)#stack enable
Enable stacking. This unit actively participates in stacking
stacking is enable. optical monitoring for stacking ports 1/2/1, 1/2/4 is not
available.
ICX7450- 32Q Router(config-unit-1)#
UNIT 11:
ICX7750-32Q Router(config)#stack unit 1
ICX7750-32Q Router(config-unit-1)#stack suggested-id 11
ICX7750-32Q Router(config-unit-1)#stack enable
Enable stacking. This unit actively participates in stacking
stacking is enable. optical monitoring for stacking ports 1/2/1, 1/2/4 is not
available.
UNIT 12:
ICX7750-32Q Router(config)#stack u 1
ICX7750-32Q Router(config-unit-1)# stack suggested-id 12
ICX7750-32Q Router(config-unit-1)#stack enable
Enable stacking. This unit actively participates in stacking
stacking is enable. optical monitoring for stacking ports 1/2/1, 1/2/4 is not
available.
4. After configuration connect the devices in a stack topology. The active controller retains its ID. The
rest of the units are assigned unique ID numbers depending on the sequence in which they are
connected or depending on the stack suggest-ID configured. Except the active controller rest of the
units reset and upon boot up, stack is formed.
NOTE
Since all the units are clean unit, enter "stack unit 1" on the respective device to configure stack
suggested id or priority.

Debugging and verification using show commands

show stack
Enter the show stack command at the device level. In the following output, the user can verify the units
in the Brocade ICX7750 stack.
ICX7750-48F Switch#show stack
T=9m57.1: alone: standalone, D: dynamic cfg, S: static, A=10, B=11, C=12
ID
1
S ICX7750-48XGF active
2
D ICX7750-48XGF standby cc4e.246d.8d80
3
D ICX7750-48XGF member
4
D ICX7750-48XGF member
5
D ICX7750-20QXG member
6
D ICX7750-20QXG member
7
D ICX7750-20QXG member
8
D ICX7750-20QXG member
9
D ICX7750-48XGC member
10 D ICX7750-48XGC member
11 D ICX7750-48XGC member
Brocade ICX 7450, Brocade ICX 7750, and Brocade ICX 7250 Stacking Deployment Guide
53-1003581-03
Type
Role
Mac Address
cc4e.246d.9e00 128 local
cc4e.246d.9b00
cc4e.246d.9c80
cc4e.2439.2a80
cc4e.2439.3700
cc4e.2439.3880
cc4e.2439.2d00
cc4e.2439.1a00
cc4e.2439.1680
cc4e.2439.1d80
Debugging and verification using show commands
Pri State
Comment
Ready
0 remote
Ready
0 remote
Ready
0 remote
Ready
0 remote
Ready
0 remote
Ready
0 remote
Ready
0 remote
Ready
0 remote
Ready
0 remote
Ready
0 remote
Ready
51

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Icx 7750Icx 7250 stacking

Table of Contents