3.2 ENGINEERING MODE OVERVIEW

Eng 0
"Eng1" appears in
"Eng0" appears in
the time window
the time window
"HARDWARE
"DISPLAY TEST"
TEST" scrolls in
scrolls in matrix or
matrix or is static in
is static in text box
text box
Press
Enter to
Enter to
Select
1. Basic function test
1. All light up as default.
1.1 ECB motor
2. Stop turns off all lights
3. Start turns on all lights
- Drive ECB motor up/down using
4. All numerical displays
resistance +/- buttons
increase by 1 when
- ECB counts shows in resistance window
resistance up is pressed.
or left top window
5. All numerical displays
- Drive elevation motor up/down using
decrease by 1 when
incline +/- buttons.
resistance down is
- Incline ADC value shows in incline
pressed
window or right top window.
6. All alpha-numerical
- Display heart rate value when heart rate
detected.
displays change from A to
1.2 Induction Brake
Z after each incline up
- Change from PWM1 to PWM5 using
key press
resistance +/- buttons
7. All alpha-numerical
- PWM value shows in resistance window
display change from Z to
A after each incline down
or left top window.
key press
- Drive elevation motor up/down using
8. Matrix display lights
incline +/- buttons.
one row up from bottom
- Incline ADC value shows in incline
to top if a up arrow key is
window or right top window.
pressed.
- Display heart rate value when heart rate
9. Matrix display lights
detected.
one row up from top to
- Press enter to go to USB port test
bottom if a down arrow
key is pressed.
2. USB port test
- "USB PORT TESTING..." scrolls in
10. All the other keys or if
matrix or is static in text box.
there is keys without an
- "PASS" scrolls in matrix or is static in
associated display
text box if passed test. OR "FAIL" scrolls
defined as above, display
in matrix or is static in text box if failed in
the physical key matrix as
"Cxdx" in the left top
test.
window and key code in
- Press enter to go to Wi-Fi testing
the right top window.
Note:
1. USB port testing is only for the consoles which have USB interface.
2. First Boot flag is only used for consoles which work for different machine and/or model types.
3. A text box must be implemented when multi language is available.
4. Console goes to model selection after cycling the power when First Boot flag is set to ON.
5. If there is confliction between process number "Px" and other display items, the process number will only display
for 1 second and then display the real items.
6. Display items alternatively when a few items needs to be displayed in the same window. Light up the indictor if the
indicator exists.
7. A text box or LED/LCD matrix is needed if the console work for different machine and/or model types.
CHAPTER 4 : Engineering Mode
Eng 1
Press
Select
1. Standard or Metric selection.
- P1 flashes in left top window
- Switch MILE or KM using Start or +/- button
- The display will show "0" for miles or "1" for km on the right top window OR
- The display will show "STANDARD" or "METRIC" statically in the middle of text
box
- Press Enter to save selection and go to language selection
2. Language selection
- P2 flashes in left top window
- Use +/- button to select language
- The display will scroll newly selected language when key is
pressed.
- Press Enter to save selection and go to machine selection
3. Machine selection
- P3 flashes in left top window
- Use +/- button to select a machine type from Treadmill, Elliptical,
Bike and Ascent trainer.
- Scroll the full name in matrix or static in the middle of text box.
- Press Enter to go to model selection
4. Model selection
- P4 flashes in left top window
- Use +/- button to select a model from the narrowed down model list.
- Scrolls the mode name in matrix or static in the text box.
- Press enter to save the selection and go to energy saver selection
5. Energy mode selection.
- P5 flashes in left top window
- Use +/- button to switch between ON/OFF
- Display ON/OFF in the right top window OR
- Scrolls "ENERGY SAVER ON" or "ENERGY SAVER OFF" in matrix
or text box.
- Press enter to save the selection and go to first boot selection.
6. First Boot selection
- P6 flashes in left top window
- Switch "First Boot" Flag using +/- button
- The display will show "0" for OFF or "1" for ON statically on the right side OR
- The display will show "ON" or "OFF" statically on the right side when +/- button
is pressed to change
- Press enter to save current setting and back to standard or metric
selection
Eng 2
"Eng2" appears in
the time window
"SWITCH
FUNCTION" scrolls
in matrix or is static
in text box
Press
Enter to
Select
Eng 3
"Eng3" appears in
the time window
"INFORMATION"
scrolls in matrix or
is static in text box
Press
Enter to
Select
1. Program accelerator
- P1 shows in the left top window
- The multiple of program time defaults to 1 and
1. Accumulated information
display in the time window or right top window.
- Time window will show
- Press +/- to change it from 1 to 100.
accumulated time.
- Press enter to save the settings and navigate to
- Distance window will show
next mode.
accumulated distance.
2. Clear user's data
- Press enter to review software
- P2 shows in the left top window
version
- Clears Accumulated time and distance, and
change to the default value in ENG8, in Puser, in
2. Software version
elog, in RCT , and so on .
- Display the UCB software
- The Brickyard will scroll "CLEAR" or " NO
version the same way as
CLEAR".
powering up.
- if there is no matrix, the TIME window show
- Press enter to review MCB
"0" for "CLEAR "or "1" for "NO CLEAR".
version
- If the data is not cleared, hold START for 5s to
clear.
3. MCB version
- Press ENTER to set to next mode P3.
- Display the MCB version on
3. Burn-in period check
screen in an appropriate way.
- P3 shows on left top window
- Press enter to navigate back to
- Burn-in period appears in time window with unit
accumulated information
hour
- Press ENTER to set next mode "P4",
4. Quick Standby mode access
- P4 shows on left top window
- The Brickyard will scroll "PRESS START
BUTTON TO ENTER STANDBY MODE"
- Press Start button to enter standby model
instantly.
- Press Enter again to skip and navigate to "P5"
mode.
5. RPM Simulator
- P5 shows on left top window
- The Brickyard will scroll "RPM"
- +/- adjusts an rpm signal from 0 (off) t0 140.
- Resetting power will reset to 0 (off)
- Press Enter again to skip and navigate to "P1"
mode.
Eng 8
"Eng8" appears in
the time window.
"TEST" scrolls in
matrix or is static in
text box
Press
Enter
to
Select
14

Advertisement

Table of Contents
loading

This manual is also suitable for:

Evolve 5

Table of Contents