5-4. Remote Voltage/Amperage Control

1
Example: Combination Remote Amperage Control (Stick) With Remote On/Off Control
Set Remote
Set V/A
Adjust Switch
Process
Example: Combination Remote Amperage Control (TIG) With Remote On/Off Control
Set V/A
Set Remote
Adjust Switch
Process
D502K 5+4
Set Range
Control Not
Used In Remote
Stick Mode
Set Range
Set Control
1
Remote 14 Receptacle RC14
Connect optional remote control to
RC14 (see Section 4-9).
In Example:
Process = Stick (Using Remote On/Off)
Range = 125 to 400 A DC
Min = 125 A DC
Max = 400 A DC
Max (400 A DC)
Min (125 A DC)
Adjust Optional Remote Control
In Example:
Process = TIG (Using Remote On/Off)
Range = 40 to 330 A DC
Percentage Of Range = 50%
Min = 40 A DC
Max = About 185 A DC (50% of 40 to 300)
Max (185 A DC)
Min (40 A DC)
Adjust Optional Remote Control