10-3. Troubleshooting Values For Circuit Diagram (Use With Section 10-2)

Voltage Readings
a)
Tolerance –
b)
Condition – 70
machine (no warm-up); no load
c)
Reference – single arrow: reference
to circuit common (lead 42); double
arrow: reference to points indicated
d)
Process/Contactor Control switch S6
in Weld Terminals Always On – CC
Stick position unless noted
e)
Wiring Connections – see Section 12
V1
126 – 130 volts ac
V2
126 – 130 volts ac
V3
252 – 260 volts ac
V4
27 volts ac
V5
101 volts ac
V6
175 volts ac
V7
+135 volts dc
V8
+ 89 volts dc
V9
+89 volts dc (S6 in Weld Terminals Always
On –Stick position)
+33 volts dc (S6 in Weld Terminals Always
On–Scratch Start TIG position)
+11.5 to 40.5 volts dc from min to max of
R1 (S6 in Weld Terminals Always On –
MIG position)
V10
69 volts ac (R1 at max.)
V11
69 volts ac (R1 at max.)
V12
69 volts ac (R1 at max.)
V13
+89 volts dc (S6 in Weld Terminals Always
On – Stick position)
47 volts dc (S6 in Weld Terminals Always
On – Scratch Start Tig position)
+16 to 56 volts dc from min to max of R1
(S6 in Weld Terminals Always On – MIG
position)
V14,
+12 volts dc with Start/Preheat switch S1 in
V15,
Preheat position
V16
V17
0 to +10 volts dc from min to max of R1
V18
+12 volts dc
V19
0 to +10 volts dc from min to max of R1
V20
+12 volts dc
V21
+12 volts dc
V22
258 volts ac with Process/Contactor
Controlswitch S6 in Stick position
V23,
18 volts ac with Process/Contactor
V24
Control switch S6 in Stick position
TM-4412 Page 42
±
10% unless specified
°
°
F (21
C); cold
Test Equipment Needed:
Resistance Values
±
a)
Tolerance
10%
specified
°
b)
Condition – 70
F (21
machine (no warm-up)
c)
Wiring Connections – see
Section 12
d)
Stop engine before checking
resistance
R1 thru R6
Less than 1 ohm
R7
18.5 ohms
R8
14.2 ohms
R9 thru R11
Less than 1 ohm
R12
15 ohms
R13
Less than 1 ohm
Amperage Readings
±
a)
Tolerance –
5% unless specified
°
b)
Condition – 70
F (21
machine (no warm-up); no load
c)
Process/Contactor
switch S6 in Weld Terminals
Always On – CC Stick position
unless noted
I1
6.3 amps dc
I2
4.3 – 4.6 amps dc
unless
°
C); cold
°
C); cold
Control
D502K 5+4