Configuring the energy meters
1. If energy meters are connected to the Sunny Home Manager, select the energy meter type
connected to the respective meter input in the drop-down lists Meter input 1, Meter input 2
and Meter input 3:
Connected energy meter type
Energy meter with D0 interface
Bidirectional meter with D0 interface
Energy meter with S0 interface
SMA Energy Meter
No energy meter
2. Select [Next].
☑ The page Extended PV System Properties opens.
Entering the PV System Data
1. Enter the system data.
2. Select [Next].
☑ The PV System Setup Assistant shows a summary of your entered data.
3. Select [Finish].
☑ Sunny Portal confirms successful registration of the Sunny Home Manager system in a
separate window.
4. To go to the Sunny Home Manager system, select [To the PV system].
☑ The Sunny Home Manager system opens.
5. Enter the system properties (see the user manual "Sunny Home Manager in Sunny Portal").
Installation Manual
Drop-down list
• Select D0.
• Select D0.
• Activate the field Bidirectional meter
(Supply and feed-in).
☑ The area Meter input 2 is not
available.
• Select S0.
• In the text field S0 pulses/kWh,
specify the pulse rate of the energy
meter (see energy meter
documentation).
• Select SMA Energy Meter xxx. Here,
xxx is the placeholder for the
SMA Energy Meter serial number. If
there are two SMA Energy Meters in
the PV system, select the desired
SMA Energy Meter.
• Activate the checkbox Bidirectional
meter (Supply and feed-in).
• Select no meter.