Wiring Connections - Honeywell S9200U1000 Installation Instructions Manual

Universal hot surface ignition integrated furnace control
Hide thumbs Also See for S9200U1000:
Table of Contents

Advertisement

S9200U1000 UNIVERSAL HOT SURFACE IGNITION INTEGRATED FURNACE CONTROL
IGNITER/INDUCER HARNESS PLUG CONNECTIONS
The following describes the harness plug connectors for
the igniter/inducer. See Table 3 and Fig. 3.
Table 3. Igniter/Inducer Harness Plug Connector 4-pin
(Class 1, Line Voltage).
Pin #
Reference Lettering
1
IND-HOT
2
IGN-HOT
3
IND-NEUTRAL
4
IGN-NEUTRAL
.
4
3
Fig. 3. S9200U1000 Igniter/Inducer harness plug
configuration.

Wiring Connections

Table 4 describes the wiring connections for Class 2
voltages.
Table 5 describes the wiring connections for Class 1
voltages.
See Fig. 5 on page 10 for wiring connection locations on
the board.
Table 4. Wiring Connections (Class 2, Low Voltage).
Connection
Terminal Type
(see Fig. 4)
6-position
D/1 (optional) EnviraCOM™ Data Connection (if
screw terminal
(#5 screw)
C/3
R/2
W
G
Y
Polarized 3-pin
E-COM
connector
12-pin
Main
connector
Harness
Connector
Straight Spade
24 VAC
Quick Connect
COM
Fuse Block
Fuse
69-2075—01
Function
Inducer 120 Vac
Igniter 120 Vac
Inducer Neutral
Igniter Neutral
2
1
M24907
Connects S9200U1000 to:
used)
24 volt ground
24 volt hot - Thermostat
Thermostat Heat Input
Thermostat continuous fan input
Thermostat cool input / cooling
contactor output for EnviraCOM™
thermostats
EnviraCOM™ diagnostic or
communications device
See Table 2 on page 7.
Transformer - 24 Vac
Transformer - Common
Fuse - Automotive Type - 3.0 Amps
.
Table 5. Wiring Connections (Class 1, Line Voltage).
Connection
Terminal Type
(see Fig. 4)
4-pin
Igniter-
connector
Inducer
(male
Harness
terminals)
Connector
Straight Spade
COOL
Quick Connect
EAC
HEAT
CONT
XFMR
L1
HUM
PARK
PARK
Straight Spade
Neutrals
Quick Connect
Straight Spade
Flame
Quick Connect
8
Connects S9200U1000 to:
See Table 3 on page 8
Circulator cool speed output
Electronic Air Cleaner 120 Vac Output
Circulator heat speed output
Continuous circulation
Transformer 120 Vac Output
Line 120 Vac hot power supply
Humidifier 120 Vac output
Circulator Motor Park 120 Vac Input
Circulator Motor Park 120 Vac Input
120 Vac Input Neutral, Transformer
Neutral, Electronic Air Cleaner
Neutral, Circulator Neutral, Humidifier
Neutral
NOTE:
Any connector can be
used.
Flame Sense - Signal Input (90 Vac,
current limited)

Hide quick links:

Advertisement

Table of Contents
loading