Setup

Filling Oil Unit

Only use oil appropriate for your application, auto-
matic dispensing, and the equipment's operating
temperature. Consult with machine and lube manu-
facturer for details.
The reservoir can be filled using a hand operated
pump, pneumatic pump or electric transfer pump.
Do not overfill (F
. 14).
IG
Do not operate G1 without reservoir attached.
Only use oils with viscosity at least 40 cSt.
F
. 14
IG
1. Remove fill cap (a).
2. Pour oil into reservoir to fill line (b).
3. Replace fill cap. Hand tighten cap, securely.

Priming

NOTE: It is not necessary to prime pump every time
pump is filled with lubricant.
Pump only requires priming the first time it is used or if it
is allowed to run dry.
1. Loosen pump element fitting (F
NOTE: When loosening pump element fitting, do NOT
loosen pump element. Loosening pump element will
change the output volume
20
a
b
. 15).
IG
F
. 15
IG
2. Only run pump until air is no longer dispensed with
the lubricant coming out of element fitting (F
F
. 16
IG
3. Tighten pump element fitting using two wrenches
working in opposite directions (F
. 16).
IG
. 15).
IG
332316E