Graco G1 Instructions Manual page 12

Standard lubrication pump
Table of Contents

Advertisement

Installation
Power DIN DC- 15 foot: Part No. 123358
NOTICE
Be sure when power is applied that stirring paddle
rotates clockwise (when viewed from the top). If it is
wired incorrectly paddle could rotate counter-clockwise
which will damage the pump's internal components. If
this happens, stop the pump immediately and wire unit
correctly.
Din Connector Specifications
DIN 43650 Form A, 18 mm assembled to power cable manufacturer's instructions
Rated to 6 Amps minimum at 250V AC
Cable Specifications
United States/Canada: 3 conductor 16 AWG UL62 and CSA 22.2 No. 49 listed SOOW cable with black, white,
green insulation
Europe: 3 Class-5 conductor, 1.5 mm
Japan/Taiwan: 3 conductor, 1/25 mm
SEA/India/Australia: 3 conductor, 1.5 mm
China: 3 conductor, 1.5 mm
Pin and Related Wire Color (F
Pin
Pin Name
1
‐VDC
2
+VDC
3
Not Used
4
Not Used
12
2
Agency Listed H07RN-F cable with blue, brown, green/yellow insulation
2
Agency Listed 2 PNCT cable with black, white, red insulation
2
Agency Listed H07RN-F blue, brown, green/yellow insulation
2
Agency Listed YZW cable with blue, brown, green/yellow insulation
. 4, page 13)
IG
United States / 
Europe
Canada
Black
Brown
White
Blue
Not Used
Not Used
Green
Green/Yellow
Color
SEA / India / 
Japan / Taiwan
Australia
Black
Brown
White
Blue
Not Used
Not Used
Red
Green/Yellow
China
Brown
Blue
Not Used
Green/Yellow
332316E

Hide quick links:

Advertisement

Table of Contents
loading