Operating the Combics 2

Neutral Measurement Z nm

When the Neutral Measurement
application is selected, you can use your
weighing instrument to measure the
length, surface and volume of parts that
have roughly the same specific weight.
The o symbol is displayed as the weight
unit.
Features:
– Store the weight on the weighing
instrument as reference weight
– Enter reference weight using a bar code
scanner
– Enter tare weight using a bar code
scanner
– Toggle the display between weight
and calculated value by pressing w
– Info mode for display of reference
weight by pressing w (> 2 sec)
26
To calculate the result correctly, the
average weight of a reference quantity
must be known (in the example below,
the reference is 1 meter of electrical
cable). There are 2 ways to do this with
the Combics:
– By placing the number of parts defined
for the reference value on the weighing
instrument and pressing O to store
the average piece weight.
The reference value is shown in the
numeric display, and can be changed
by pressing r.
How the reference weight is calculated
depends on the menu setting for reso-
lution (3.9). Either the value is rounded
off in accordance with the display
resolution, or the display resolution is
increased 10-fold (+1 decimal place) or
100-fold (+ 2 decimal places), or maxi-
mum internal resolution is applied.
– By entering the reference weight (i.e.,
the weight of one piece) using a bar
code scanner (menu setting: "Setup>
Bar code > Store value as reference
(ref)"). In this case, the value is stored
as a reference automatically, without
pressing the O key.
This value remains active in the reference
memory until you delete it by pressing
c, overwrite it or until you select
a different application. It also remains
stored after you switch off the Combics.
Application Parameters: Neutral Measurement
3. 5.
Minimum Load for Automatic Taring
and Automatic Printing
3. 5. 1 * 1 digit
3. 5. 2
2 digits
3. 5. 3
5 digits
3. 5. 4
10 digits
3. 5. 5
20 digits
3. 5. 6
50 digits
3. 5. 7
100 digits
3. 5. 8
200 digits
3. 5. 9
500 digits
3. 5.10
1000 digits
3. 6.
Minimum Load for Initialization
3. 6. 1 * 1 digit
3. 6. 2
2 digits
3. 6. 3
5 digits
3. 6. 4
10 digits
3. 6. 5
20 digits
3. 6. 6
50 digits
3. 6. 7
100 digits
3. 6. 8
200 digits
3. 6. 9
500 digits
3. 6.10
1000 digits
3. 7.
Automatic Taring:1st Weight Tared
3. 7. 1 * Off
3. 7. 2
On
3. 8.
Start Application with Most Recent
Application Data when Combics
is Switched On
3. 8. 1
Automatic (on)
3. 8. 2 * Manual (off)
3. 9.
Resolution for Calculation
of Reference Value
3. 9. 1 * Display resolution
3. 9. 2
Display resolution + 1
decimal place
3. 9. 3
Display resolution + 2
decimal places
3. 9. 4
Internal resolution
3.10.
Decimal Places for Display of Results
3.10. 1 * None
3.10. 2
1 decimal place
3.10. 3
2 decimal places
3.10. 4
3 decimal places
3.11.
Storage Parameter
3.11. 1* At stability
3.11. 2
At increased stability
3.13.
Reference Weighing Instrument
3.13. 1* Off
3.13. 2
WP1
3.13. 3
WP2