130. Balance Board Activity, Testing/Training (Medium Difficulty) With Time-Out. Balance board
activity will appear only on the right side of WSVT. For activity on both sides: After selecting and
entering the program, Press "0" and press "33" Now press ENTER.'''
Light appears at one of four locations. To score a point user must tilt the board to the position of
the light only when the center cue light is "on". If the center cue light is "off" no point will be
scored, the light will not move to a new position but the board must be tilted to it within the
allowed 2 seconds. If not, a time-out signal is heard, that same light position is illuminated, and
user must tilt to that position to continue (no point is scored). Total elapsed time is 60 seconds.
The center cue light flashes "on-off" 100 times/minute.
Activity (1) Time (2) Speed (3) Pattern (4) Lights (5) Timeout (6) Flash (7)
17
60
100
131. Balance Board Activity, Testing/Training (Fast Action) With Flash And Time-Out
A light appears at one of four locations for only 1/4 second. To score a point, user must tilt the
board to the position of the light only when the center cue light is "on". If the center cue light is
"off" no point will be scored. This must be done within the allowed 2.5 seconds, if not, a time-out
signal is heard, that same light position is illuminated, and user must tilt to that position to
continue (no point is scored). The center cue light flashes "on- off" 120 times/minute. Total time,
100 seconds
Activity (1) Time (2) Speed (3) Pattern (4) Lights (5) Timeout (6) Flash (7)
17
100
120
132. Balance Board Activity, Testing/Training (Fast Action) With Flash And Time-Out
A light appears at one of four locations for only 0.5 seconds. To score a point, user must tilt the
board to the position of the light only when the Center cue light is "on." If the center cue light is
"off" no point will be scored, and the light will move to a new position. This must be done within
the allowed 2.0 seconds, if not. a time-out signal is heard. That same light position is now fully
illuminated, and user must tilt to that position to continue (no point is scored). The center cue
light flashes "on-off" 120 times/minute. Total time, 120 seconds.
Activity (1) Time (2) Speed (3) Pattern (4) Lights (5) Timeout (6) Flash (7)
17
120
120
Wayne Engineering
TM
, a subsidiary of Eyecarrot Innovations Corp. in Canada, is the leading provider of high-performance
instruments for testing and enhancing visual and motor skills. Learn more at
3
4
20
3
4
25
3
4
15
0
250
500
www.wayneengineering.com
and www.eyecarrot.com.