75. Eye Hand Coordination With Both A Visual And An Auditory Stimulus
Use 4 light/switch targets, spaced as desired. Lights are self paced; trainee must respond by
pushing the lights at the instant an auditory signal is heard. Sound will be produced and a point
will be scored. 120 seconds.- 60 lights/min.
Activity (1) Time (2) Speed (3) Pattern (4) Lights (5) Timeout (6) Flash (7) Dual(0)
5
120
60

76. Pro-Action/Reactiom Screening Test Using 4 Switch/ Light Targets.

Starting speed 40 lights/minute, timed for 60 sec. Speed of the lights increases slowly for each
correct response. Speed is reduced after each missed light. At the end of time, the display
records the product of the number of correct responses multiplied by the final speed of the
lights. Maximum score is 10,000
Activity (1) Time (2) Speed (3) Pattern (4) Lights (5) Timeout (6) Flash (7) Dual(0)
14
60
100

77. Eye/Hand/Body Spatial Integration - Self Pacing

Using the 4 light/switch boxes. Space the light/switch boxes at least 6 feet apart. Speed is
important. Trainee must depress each light as rapidly as possible. If the light is not depressed
within 1.0 seconds a timeout signal is produced. The light must still be depressed, but no point
will be scored. Timed 100 sec.
Activity (1) Time (2) Speed (3) Pattern (4) Lights (5) Timeout (6) Flash (7) Dual(0)
1
100
78. Synchronized Rhythm
Space two switch/lights 24 inches apart. The lights will alternate from right to left. Trainee must
depress the first light, and the next light, keeping up with the lights. A count is recorded on the
display for each right to left movement. Lights move at 250 lights/min timed for 60 seconds.
Activity (1) Time (2) Speed (3) Pattern (4) Lights (5) Timeout (6) Flash (7) Dual(0)
16
60
300

79. Balance Board Synchronized Rhythm

Identical to the above program. Space the two switch/lights four feet apart on the wall. Connect
the balance board to the rear of the tester. Trainee must shift in rhythm with the lights. Lights
move at 100 lights/min. Timed for 120 seconds
Wayne Engineering
TM
, a subsidiary of Eyecarrot Innovations Corp. in Canada, is the leading provider of high-performance