Self Pacing With Time Out And Flash; Balance Board, Test/Training - Wayne Saccadic Fixator Instructions For Using Manual

Optometric profession's standard for testing
Table of Contents

Advertisement

127. Peripheral Awareness: Center Cue Light "On-Off" At A Constant Rate (WSVT center Que light
and sound)
The center que light will flash 60 lights/minute. The first outer light flashes "on" for 1/3 second
(0.33 sec). The outer light must be pressed while the center cue light is "On" to score a point. If
the light is pressed when the center cue light is "off" the light will move to a new location on the
outer ring. No point will be scored. If the light is not pressed within 2 seconds (time-out) that
same light position is now fully illuminated, and user must press the light to continue, NO point is
scored. Total elapsed lime is 90 seconds.
Activity (1) Time (2) Speed (3) Pattern (4) Lights (5) Timeout (6) Flash (7) Dual(0) Center (0) Sound(0)
18
90
60

128. Self Pacing with time out and Flash

Light flashes "on," light Waits, timed-out For 2.5 sec. The center cue light flashes "on-off" at a
constant rate of 100 lights/minute The first outer light flashes "on" for a half second, then goes
"off". This light must be pressed while the center cue light is "On" to score a point. If the light is
pressed when the center cue light is "off" no point will be scored, and the light will not move
until it is synchronized with the center light,. If the first light is not pressed within 2.5 seconds
(time out) that same light will appear "on", and when pressed will move to another position. No
point will be scored. A point is scored only when the outer light location is pressed while the
center fixation light is "on." This must be done within the 2.5 seconds of time-out. Total elapsed
time is 120 seconds.
Activity (1) Time (2) Speed (3) Pattern (4) Lights (5) Timeout (6) Flash (7) Dual(0) Center (0)
18
120
100
129. Balance Board, Test/Training (Slow Action)
Light appears at one of four locations (top, right, bottom, or left). To score a point, user must tilt
the board to the position of the light only when the center cue light is "on." If the center cue
light is "off" no point will be scored, and the light will not move to a new location. The center cue
light will flash "on and off" 60 times/minute. Elapsed time 120 seconds.
Activity (1) Time (2) Speed (3) Pattern (4) Lights (5) Timeout (6) Flash (7)
17
120
60
Wayne Engineering
TM
, a subsidiary of Eyecarrot Innovations Corp. in Canada, is the leading provider of high-performance
instruments for testing and enhancing visual and motor skills. Learn more at
3
2
20
3
2
25
3
4
0
750
66
500
66
0
www.wayneengineering.com
and www.eyecarrot.com.
21
11
21
36

Hide quick links: