VeriFone MX800 series Programmer's Manual page 294

Hide thumbs Also See for MX800 series:
Table of Contents

Advertisement

IPP MS
DUKPT C
AND
OMMUNICATIONS
Common Packets
294
M
X
800 S
P
ERIES
ROGRAMMERS
P
ACKETS
Table 35
Packets 09 and 14 Communication Protocol (Continued)
Master Device
06 Serial Number Check
<SI>0106<SO>{LRC}
ACK/NAK/EOT
07 UART Loopback Test
<SI>0107<SO>{LRC}
ACK/NAK/EOT
<SI>09<SUB>PROCESS-
ING<SO>{LRC}
ACK/NAK/EOT
G
UIDE
Transmit
IPP
Direction
IPP6 and earlier
ACK/NAK/EOT
<SI>14xxxxxxxxxxxxxxxx<SO>{LRC}
where, xxxxxxxxxxxxxxxx indicates the
serial number of the IPP. Length is 16
digits, for example, 1234567890123456.
EOT to terminate process.
IPP7
ACK/NAK/EOT
<SI>09<SO>{LRC}
ACK/NAK/EOT
<SI>09<SUB>PROCESSING<SO>{LRC}
EOT to terminate process.

Advertisement

Table of Contents
loading