5. Install any additional interface cables and power cables.
After you have completed these steps, continue with "Installing the FAStT100."

Installing the FAStT100

This section provides instructions on how to install the FAStT100 in a rack.

Rack mounting template

Attention:
Appendix B, "Rack mounting template," on page 105. If you want to tear out the
templates from this document for easier use, use the copies in Appendix B, "Rack
mounting template," on page 105 rather than the copies provided in this section.
Use the following templates (Figure 7 on page 17 and Figure 8 on page 18) to
identify the proper locations for inserting M6 screws when mounting the support
rails and FAST100 to a rack. The locations for the M6 screws are highlighted in the
templates.
The FAStT100 is 3 U high. Align the template with the rack at a U boundary. U
boundaries are shown as horizontal dashed lines in the rack mounting templates.
Note: The mounting holes that are shown in the following templates are square.
16
IBM TotalStorage FAStT100 Storage Server: Installation, User's, and Maintenance Guide
Duplicate copies of the rack mounting templates are provided in
The holes in your rack might be round, square, or threaded.