Fastt100 Specifications; Ibm Totalstorage Fastt100 Specifications - IBM totalstorage fastt100 Installation, User And Maintenance Manual

Storage server
Table of Contents

Advertisement

FAStT100 specifications

Table 8 lists the specifications for the FAStT100.
Table 8. IBM TotalStorage FAStT100 specifications
Size
v Width: 48.1 cm (18.97 in.)
v Height: 13.2 cm (5.21 in.)
v Depth: 59.7 cm (23.52 in.)
Weight
v Drive-ready weight (without disk drive
v Fully configured weight (with 14 disk drives
Electrical input
v Sine-wave input (50 - 60 Hz) is required
v Input voltage low range:
v Input voltage high range:
v Input kilovolt-amperes (kVA),
Environment
v Air temperature
v Humidity
Notes:
1. The nonoperating environment must not exceed the operating environment
2. The storage environment must not exceed the operating environment limits for
10
IBM TotalStorage FAStT100 Storage Server: Installation, User's, and Maintenance Guide
modules installed): 26.5 kg (58.3 lb)
installed): 40.8 kg (85.7 lb)
– Minimum: 90 V ac
– Maximum: 127 V ac
– Minimum: 198 V ac
– Maximum: 257 V ac
approximately:
– Minimum configuration: 0.06 kVA
– Maximum configuration: 0.39 kVA
– Operating:
- Altitude: 0 - 914 m (3000 ft): 10° -
35° C (50° - 95° F)
- Altitude: 914 m - 2133 m (3000 -
7000 ft): 10° - 32° C (50° - 90° F)
Important: The recommended
operating environment air temperature
is 22° C (72° F) or lower.
– Storage:
- Altitude: 0 - 914 m (3000 ft): 1° - 60°
C (33° - 140° F)
– 8% - 80%
– Noncondensing
limits for longer than 60 days.
longer than 1 year.
Heat dissipation
v Fully configured storage server (14 1.5
Gbps SATA hard disk drives)
– 1088 BTU per hour
Acoustical noise emission values
For open bay (0 drives installed) and typical
system configurations (eight hard disk drives
installed):
v Sound power (idling):
– 5.9 bel (open bay)
– 6.1 bel (typical)
v Sound power (operating):
– 5.9 bel (open bay)
– 6.2 bel (typical)
v Sound pressure (idling):
– 44 dBA (open bay)
– 46 dBA (typical)
v Sound pressure (operating):
– 44 dBA (open bay)
– 47 dBA (typical)
These levels are measured in controlled
acoustical environments according to ISO
7779 and are reported in accordance with
ISO 9296. The declared sound power levels
indicate an upper limit, below which a large
portion of machines operate. Sound pressure
levels in your location might exceed the
average 1-meter values stated because of
room reflections and other nearby noise.

Advertisement