Pioneer PDP-505HD Service Manual page 40

Hide thumbs Also See for PDP-505HD:
Table of Contents

Advertisement

PDP-505HD
Pin Function
Pin
Name
No.
1
S2_DET
S2 Signal detection
OPTION
Option Video Box detection
2
2
SCL
I
C-BUS Clock
2
3
SDA
I
C-BUS Data
4
V_DETI
Result of Y signal detection
5
PN_BUSY BUSY signal from Panel U-Com
6
–––––
No allocation(not used)
7
CLK2
Clock output for Serial 3 lines
8
DATA2
Data output for Serial 3 lines
9
DTO_SU
Serial data input from SYNC u-com
10
VOL
Audio volume output
11
RST RET
Reset Signal from Digital Video Assy
(Panel u-com and IP u-com)
12
–––––
No allocation (not used)
13
–––––
No allocation (not used)
14
CTS
Not used
15
REQ_SU
Request to read detected frequency from
SYNC u-com
16
RST_SU
Reset Signal from SYNC u-com
17
EP_RST
Reset output to E
18
BUSY2
Not used
19
SCL2
Not used
20
TXD
RS-232C sending data
21
RXD
RS-232C receiving data
22
REM
Remote Control unit signal input
23
KEY
Key Matrix, Key of the unit input
24
CNVSS
Controlling operation mode of u-com of
the unit
25
*RST
Reset input
26
POWER
Power on/off
27
–––––
No allocation (not used)
28
X_IN
Clock input
29
X_OUT
Clock output
30
VSS
Power supply terminal
31
SC_DT
Detecting SYNC Signal output from Analog High: existence of Sync signal, Low: non existence
(ULK_PLL) Assy to Digital Assy
32
RTS
Not used
33
RMT
Signal of request to quit sending
commands from Panel u-com
34
PN_ERR
Communication error signal from Panel u-com Low: Normal
35
*PN_RST
Reset signal output to Panel u-com & IP u-com High: Normal, Low: In Reset
36
–––––
No allocation (not used)
37
*GRN
Green LED lighting
38
*RED
Red LED lighting
40
Function
0–1.3V: Normal, 1.4–2.4V: Letter Box, 2.5–5V: Squeeze
High: non existence, Low: existence of Video Box
0–5V clock signal: always communicating when power on
0–5V clock signal: always communicating when power on I/O
High: Y Signal detected, Low: Y Signal not detected
High: In exchanging input functions, Low: Normal
0–5V clock signal: always communicating when power on
0–5V serial signal: always communicating when power on
(both-way communication with Full Auto Zoom IC )
High: Normal, 0–5V serial signal: During communication
PWM output
High: Normal, Low: In Reset
High: Normal, Low: In requesting
High: Normal, Low: In resetting
2
PROM
High: In resetting, Low: Normal
0–5V serial signal
0–5V serial signal
High: Normal, 0–5V serial signal: In input from Remote
Control unit
High: Normal, 0–5V serial signal: In Key input
Low: Normal
High: Normal, Low: In Reset
High: When power on, Low: In Stand-by
10 MHz sine wave
10 MHz sine wave
STB GND
Low: Normal
Low: In lighting Green LED
Low: In lighting Red LED
Operation of Terminals (during power on)
PDP-
PDP-
PDP-
I/O
502MX
502MXE
505HD
I
––
I
––
––
O
I
I
O
O
I
O
––
I
I
I
O
O
I
I
I
I
I
O
I
O
I
I
I
I
O
O
O

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents