Siemens OP5 Equipment Manual page 137

Operator panel
Table of Contents

Advertisement

Message
Cause
$ 005
Internal error
$ 006
Error during data transfer in Down-
load mode
(message with two variables)
Var. 1
Var. 2
1
3
5
6
7
8
9
10
11
$ 040
No response from PLC
– Cable defective or not
plugged in
– Character delay time too
short (FAP only)
$ 041
Temporary driver error
$ 100
Invalid RAM contents
$ 104
Download mode canceled by pres-
ing a key
$ 106
Serious error eliminated and key
pressed
$ 108
Mode change
$ 110
Mode change
$ 114
PLC cold restart
$ 115
Establishment of logical link
$ 117
Connection to PLC OK again fol-
lowing a fault
$ 119
Automatic start of OP (password
list is not compulsorily deleted)
$ 125
Language changed by standard
screen or PLC job
$ 131
Mode change
$ 133
Mode change
Manual OP5, OP15
( ) J31069-D0840-U001-A2-7618
Action
Check connection, repeat download
Status display
Internal error
Timeout error
Parity error
Framing error
Overrun error
Line interruption
Receive buffer overflow
Wrong control character
Internal error
System Messages
– Check physical connection
– Modify and repeat download configu-
ration or PLC program
– Restart PC
– Download configuration