Message
Cause
$ 533
No connection between OP and
floppy disk station
Connection cable not plugged in
or is defective
Error on the floppy disk station
Floppy disk station not ready
$ 534
No more memory space on the
floppy disk
$ 535
No floppy disk inserted
Floppy disk defective
Floppy disk not formatted
$ 536
Malfunction in the connection be-
tween OP and floppy disk station
Connection cable defective or
not plugged in correctly
$ 537
Read access to blank floppy disk
$ 538
Simultaneous access to data record
via job and operator input
$ 540
Maximum number of data records
already set up
$ 600
Wrong parameter transferred by
ProTool/Lite
(overflow warning)
$ 601
Wrong parameter transferred by
ProTool/Lite
(message log)
$ 602
Wrong parameter transferred by
ProTool/Lite
(remaining buffer size)
$ 604
Message not configured for a set
message bit
$ 613
Data block does not exist or is too
short
$ 615
Line to be output is larger than the
reserved print memory or the num-
ber of control sequences is too large
$ 616
$ 617
B-8
Action
Insert a blank, formatted floppy disk and trig-
ger transfer again.
Insert new, formatted floppy disk
Repeat access which was not executed
Set required value by means of standard
screen or PLC
Set required value by means of standard
screen or PLC
Re-configure and repeat download of required
value
Configure messages and transfer
Create DB of requisite length in PLC
Check configuration for log
See Internal Errors