Electrical system
Disconnect the control unit connector and the coil connector.
Verify the coil connector PIN 1 ground insulation (or control unit connector PIN 1). Restore
the cabling if necessary.
RIGHT COIL
Level in electrical circuit diagram:Right coil and
injector
Location:
centred under the fuel tank.
connector: on the coils.
Electrical characteristics:
Primary winding resistance: 550 k ±
10%
Secondary winding resistance: 3 k ±
10%
Tube resistance 5 k
Pin-out:
1. Power (red/brown cable)
2. Power ground 2 (blue cable)
3. Circuit ground (orange/red cable)
ELECTRICAL ERRORS
H.V. Coil P0352 - shorted to positive / open circuit or shorted to negative.
Error cause
Shorted to positive: excessive voltage at PIN 8 of the control unit connector.
Circuit open or shorted to negative: interruption of the circuit or null voltage at PIN 8 of the control unit
connector.
Troubleshooting
Shorted to positive:
Disconnect the coil connector, turn the key to ON and activate the component through the
diagnostics instrument.
Verify the presence of voltage on the coil connector PIN 3: if present, restore the cabling,
otherwise replace the coil.
The circuit is open:
Carry out the check procedure of the coil and control unit connectors.
Verify continuity of the cabling between the coil and control unit: Coil PIN 3 - control unit PIN
8. In the absence of continuity restore the cabling.
ELE SYS - 98