Chapter 10.
Press "Power" button and press two buttons(Function and Temp.) within 10 sec.The screen displays
"TEST", the test programme will start, the LED lamp will light in turn.
Order
Operation
Pressing "Function" button
1
Pressing"Start Pause"button
2
3
Pressing"Selection"button
Pressing "Dry level" button
4
Pressing "Mode"button
5
Display and action
The screen will display the programme version.
The screen will display in turn:
A) "8888"
the motor ready to run;
B "7777" only the motor is running;
C "6666"
only the fan will run 5 seconds;
only the pump will run 5 seconds;
D "5555"
"END"
E
The third LED screen will display the state of water level switch:no water
is 0,full of water(there is much water to make floater up) is 1;
The fouth LED screen will display the state of door switch:open is 0,close
is 1.
Put damp load in the drum.
Press"Dry level" button,the drum will run for 60
and the compressor begin to star at the same time.The screen will
display the humidity of load.
After 60 seconds,the screen display "end".5 seconds later,the motor and
the compressor stop working.
Notice:dont open the door or turn the knob in the phase .
The screen will display the temperature of NTC2 and NTC3 in turn