Insufficient collation area
Light sequence:
Secondary light sequence:
Press
sequence.
Message:
Printer memory does not have the free space necessary to collate print job. May occur due to one of the errors
listed below:
Solution:
Turn printer off and back on to try printing the page again. If not successful:
To avoid this error in the future:
Load media
Light sequence:
Message:
Printer is out of media, or media did not feed properly.
Solution:
Downloaded From ManualsPrinter.com Manuals
Using the operator panels
Continue—On
Error—On
twice quickly to see the secondary light
Continue—On
Toner Low/Replace PC Kit—On
Error—On
Printer memory is full.
A page is too complex to print.
Memory is insufficient to save what is in the print buffer.
Press
to clear message and continue processing the job (some print data may be lost).
Reduce complexity of the page by reducing the amount of text or graphics.
Set Page Protect to On in the Local Printer Setup Utility (see Software and Documentation CD).
Continue—On
Load / Remove Paper—On
Load media into Tray 1 or priority feeder, and press
Ensure media is loaded correctly in Tray 1 or priority feeder.
Press
to cancel print job.
Overview of the Lexmark E120n operator panel
Primary light
sequence
to resume.