Connection of two strings (standard)

Two strings can be connected to the Sunmaster directly.
See section 3.6 for the maximum power connected to
each Solar-input. The total input power must be distributed
equally over both Solar-inputs as much as possible.
See figure 3-2.
String 1
DC
Figure 3-2
Figure 3-3: Y-adapter
10
.co.uk
String 2
AC
AC grid
Mon-Fri:
8:30am - 6:30pm
3.8.2
Connection of more than two strings
(option)
In case more than two strings should be connected to the
Sunmaster, Multicontact Y-adapters may be used to
combine the strings (see figure 3-3 and ordering
information chapter 8). The strings connected to the same
Solar-input should exist of an equal number of identical
PV-modules. See figure 3-4.
String 1 + 2
MultiContact
Y-adapters
Figure 3-4