Lcd Initial Data Input - Sony MVC-FD83 Service Manual

Hide thumbs Also See for MVC-FD83:
Table of Contents

Advertisement

1. LCD Initial Data Input

Mode
Signal
Adjustment Page
Adjustment Address
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, and enter the data given in the following table.
Note: Press the PAUSE button of the adjusting remote commander
each time the data are set, as the data are written to non-
volatile memory (EEPROM).
Address
Data
FD83 FD88
80
BB
BC
81
6F
80
82
77
B9
83
7A
B7
84
DB
BE
85
78
C8
86
70
7C
87
6F
50
88
97
74
89
51
72
8C
9A
9A
8D
6F
50
8E
13
13
8F
00
00
Processing after Completing Adjustments:
1) Select page: 0, address: 01, and set data: 00.
PLAY
Arbitrary
D
80 to 89, 8C to 8F
Remark
Bright Adjustment
Color Adjustment
White Balance Adjustment
Contrast Adjustment
D Range Adjustment
V-COM Level Adjustment
VCO Adjutment (NTSC)
V-COM Adjustment
Fixed value
VCO Adjutment (PAL)
Fixed value
2. VCO Adjustment (NTSC) (PK-47/48 Board)
Set the VCO free-run frequency. If deviated, the LCD screen will
be blurred.
Mode
Signal
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 5, address: F0, and set data: 01.
3) Select page: D, address: 87, change the data and set the fre-
quency (f) to the specified value.
4) Press the PAUSE button of the adjusting remote commander.
Processing after Completing Adjustments:
1) Select page: 5, address: F0, and set data: 00.
2) Select page: 0, address: 01, and set data: 00.
5-28
PLAY
Arbitrary
Pin (7) of CN801 (HSY)
Frequency counter
D
87
f = 15734 ± 30 Hz