4. Switch Check (2)
Page 2
Using method:
1) Select page: 2, addresses: 54 to 58.
2) By discriminating the dispaly data, the pressed key can be
discriminated.
Address
00 to 13
54
VOLUME+
(KEY AD0)
(PK-47/48 board) (PK-47/48 board)
(IC303 &•)
(S705)
55
CONTROL DOWN CONTROL UP
(KEY AD1)
(PK-47/48 board) (PK-47/48 board) (PK-47/48 board) (PK-47/48 board) (PK-47/48 board)
(IC303 &ª)
(S701)
56
CONTROL RIGHT CONTROL LEFT CONTROL SET
(KEY AD2)
(PK-47/48 board) (PK-47/48 board) (PK-47/48 board) (PK-47/48 board)
(IC303 *º)
(S701)
57
(KEY AD3)
(IC303 *¡)
58
(KEY AD4)
(IC303 *™)
5. Self Diagnosis Code
Display Code
Countermeasure
Change the disk and turn off the main
C:32:01
power then back on.
Replace the floppy disk.
C:13:01
Format the floppy disk with the MVC-
FD83/FD88.
E:91:01
Repair by service engineers only.
*1
C:63:00
E:61:00
*1
C:63:10
E:61:10
Note : The error code is cleared if the battery is removed, except defective flash.
*1 : The error display is given in two ways.
*2 : When the flash charging failed, Page:D, Address:C7, Data:04 are written.
After repair, be sure to write Page:D, Address:C7, Data:00.
[Power supplying Method]
Use the AC power adaptor (BC-V615) when supplying the power to this set.
Address 54 to 58
14 to 3A
3B to 63
VOLUME –
(S707)
DISPLAY
(S701)
(S704)
(S701)
(S701)
Data
64 to 90
91 to BC
BRIGHT+
BRIGHT–
(S711)
FLASH
(S708)
PICTURE EFFECT PROGRAM AE
(PK-47/48 board) (PK-47/48 board)
(S703)
Cause
Defective floppy disk.
• The type of floppy disk that cannot be
used by this machine, is inserted.
(Such as 2DD)
• Data is damaged.
• Unformatted disk is inserted.
*2
Abnormality when flash is being
charged.
When failed in the focus initialization.
When failed in the zoom initialization.
5-37 E
5-37
BD to E8
(S712)
LCD BACKLIGHT LCD BACKLIGHT
OFF
(PK-47/48 board) (PK-47/48 board)
(S713)
(S709)
FOCUS
MANUAL
(MF UNIT)
Caution Display During Error
DRIVE ERROR
DISK ERROR
Flash LED
Flash display
Flashing at 3.2 Hz
—
E9 to FF
ON
(S713)
FOCUS AUTO
(MF UNIT)