System Control System Adjustments; Battery Down Adjustment; Alignment Check (Fdd Unit) - Sony MVC-FD83 Service Manual

Hide thumbs Also See for MVC-FD83:
Table of Contents

Advertisement

1-6.

SYSTEM CONTROL SYSTEM ADJUSTMENTS

1. Battery Down Adjustment

Set the battery end voltage.
If the voltage is incorrect, the life of battery will shorten.
The image at the battery end will also be rough.
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Connection:
1) Connect the regulated power supply and the digital voltmeter
to the battery terminal as shown in Fig. 5-1-28.
Adjusting method:
1) Adjust the output voltage of the regulated power supply so
that the digital volt meter display is 6.1 ± 0.1 Vdc.
2) Turn the HOLD switch of the adjusting remote commander.
3) Turn on the power.
4) Select page: 0, address: 01, and set data: 01.
5) Decrease the output voltage of the regulated power supply so
that the digital voltmeter display is 5.80 ± 0.01 Vdc.
6) Select page: 2, address: 51, read the data, and this data is named
Dref.
7) Select page: D, address: 30, set data Dref, and then press the
PAUSE button of adjusting remote commander.
8) Convert Dref to decimal notation, and obtain Dref'.
(Refer to Table 5-2-1. "Hexadecimal-decimal conversion
table")
9) Calculate D31, D32, D33 and D34 using following equations
(decimal calculation), convert it to a hexadecimal number, and
input each adjustment address.
Address: 31
D31'=Dref'+8
Address: 32
D31'=Dref'+23
Address: 33
D31'=Dref'+44
Address: 34
D31'=Dref'+55
Note: After setting each data, be sure to press the PAUSE but-
ton.
Processing after Completing Adjustments:
1) Select page: 0, address: 01, and set data: 00.
Regulated power supply
5.80 ± 0.01 Vdc
STILL
All black (Cover the lens with a
black cap)
Displayed data of page: 2,
address: 51
Adjusting remote commander
D
30 to 34
Digital voltmeter

2. Alignment Check (FDD Unit)

Confirm that the FDD alignment is within the specifications.
If deviated, reading and writing data from and to floppy disk be-
come impossible.
Or compatibility of floppy disk with other machines can be lost.
Mode
Signal
Measurement Point
Measuring Instrument
Specified Value
Checking method:
1) Disconnect the adjusting remote commander.
2) Insert the alignment disk TFD2-1 (+) (+17.5 um).
3) Playback arbitrary signal and check that the playback picture
is normal.
4) Insert the alignment disk TFD2-1 (–) (–17.5 um).
5) Playback arbitrary signal and check that the playback picture
is normal.
Power cord
(J-6082-223-A)
Fig. 5-1-28
5-33
PLAY
Alignment disks (TFD2-1 (+))
and (TFD2-1 (-)):
Arbitrary signal
Check on LCD screen
The playback pictures should be
normal