316 – AL Timing Cylinder B6
Cause
Time-of-flight measuring fault of
injector: Time-of flight measured
value extremely low or extremely
high.
317 – AL Timing Cylinder B7
Cause
Time-of-flight measuring fault of
injector: Time-of flight measured
value extremely low or extremely
high.
318 – AL Timing Cylinder B8
Cause
Time-of-flight measuring fault of
injector: Time-of flight measured
value extremely low or extremely
high.
319 – AL Timing Cylinder B9
Cause
Time-of-flight measuring fault of
injector: Time-of flight measured
value extremely low or extremely
high.
320 – AL Timing Cylinder B10
Cause
Time-of-flight measuring fault of
injector: Time-of flight measured
value extremely low or extremely
high.
104 | Troubleshooting | M015710/04E 2012-09
ZKP-Number: 1.8004.515
Corrective action
u Replace injector concerned if the fault message appears
frequently (→ Page 146).
ZKP-Number: 1.8004.516
Corrective action
u Replace injector concerned if the fault message appears
frequently (→ Page 146).
ZKP-Number: 1.8004.517
Corrective action
u Replace injector concerned if the fault message appears
frequently (→ Page 146).
ZKP-Number: 1.8004.518
Corrective action
u Replace injector concerned if the fault message appears
frequently (→ Page 146).
ZKP-Number: 1.8004.519
Corrective action
u Replace injector concerned if the fault message appears
frequently (→ Page 146).