MTU M015710/04E Operating Instructions Manual page 88

Table of Contents

Advertisement

311 – AL Timing Cylinder B1
Cause
Time-of-flight measuring fault of
injector: Time-of flight measured
value extremely low or extremely
high.
312 – AL Timing Cylinder B2
Cause
Time-of-flight measuring fault of
injector: Time-of flight measured
value extremely low or extremely
high.
313 – AL Timing Cylinder B3
Cause
Time-of-flight measuring fault of
injector: Time-of flight measured
value extremely low or extremely
high.
314 – AL Timing Cylinder B4
Cause
Time-of-flight measuring fault of
injector: Time-of flight measured
value extremely low or extremely
high.
315 – AL Timing Cylinder B5
Cause
Time-of-flight measuring fault of
injector: Time-of flight measured
value extremely low or extremely
high.
ZKP-Number: 1.8004.510
Corrective action
u Replace injector concerned if the fault message appears
frequently (→ Page 146).
ZKP-Number: 1.8004.511
Corrective action
u Replace injector concerned if the fault message appears
frequently (→ Page 146).
ZKP-Number: 1.8004.512
Corrective action
u Replace injector concerned if the fault message appears
frequently (→ Page 146).
ZKP-Number: 1.8004.513
Corrective action
u Replace injector concerned if the fault message appears
frequently (→ Page 146).
ZKP-Number: 1.8004.514
Corrective action
u Replace injector concerned if the fault message appears
frequently (→ Page 146).
M015710/04E 2012-09 | Troubleshooting | 103

Advertisement

Table of Contents
loading