Power Supply
Gas Supply Pipe
Approved Gas Type
Gas Pressure
Approved Vent Materials
Recommended Minimum
Clearance for Servicing
Water Supply Pressure
ECO Limit
Pressure Switch Setting
(normal altitude)
Temperature Setpoint Range
Dedicated 120VAC, 60 Hz, 15A
Minimum 1/2" (Schedule 40 black iron pipe
recommended)
Natural or Propane; unit must match gas type supplied
5" w.c. minimum for Natural Gas; 11" w.c. for Propane;
14" w.c. maximum for Natural Gas / Propane
Single or Double Wall Metal Vent Pipe
18" from top; 24" from front; 4" from sides and rear
150 psi maximum allowable working pressure; check local
codes for supply pressure
188°F (87°C)
-0.20" w.c. (-0.10" for Hi-Alt.)
60°F (16°C) to 160°F (71°C); approximate temperatures