Specifications - Bradford White UPV75 Series Service Manual

Ultra low nox through-the-wall gas water heaters
Table of Contents

Advertisement

UPV75 Series

Specifications

Power Supply
Gas Supply Pipe
Approved Gas Type
Gas Pressure
Venting System
Approved Vent
Materials
Minimum Clearance for
Servicing
Water Supply Pressure
Gas Control ECO Limit
Residential
Temperature Set Point
Range
Commercial
Temperature Set Point
Range
Blower Temperature
Switch
Pressure Switch
Blower
HIGH ALTITUDE INSTALLATIONS
This appliance has been certified for installations up to 10,100 ft above sea level without modification. Installations greater
than 10,100 ft above sea level are not intended. Unauthorized modifications may result in unsafe operation.
WARNING: In order to assure the safe and efficient performance of the water heater, it is necessary to follow the vent
connector length rules shown below. Failure to adhere to these rules can result in the unsafe operation of the appliance.
6
Dedicated 115 VAC, 60 Hz, 15A.
Minimum 1/2" NPT (schedule 40 black iron pipe recommended).
Natural Gas, unit must match gas type supplied.
6.0" W.C. min. for Natural Gas, 14.0" W.C. maximum.
Power vent through the wall or vertical through the roof.
PVC, CPVC or ABS.
18" from top, 24" from front, 4" sides and rear.
150 PSI maximum allowable working pressure. Check local codes for
supply pressure.
Residential 188°F (87°C), Commercial 199°F (93°C).
60°F (16°C) to 160°F (71°C) (approximate temperatures).
80°F (27°C) to 180°F (82°C) (approximate temperatures).
Normally closed, opens @ 155°F (68°C), auto reset @ approximately
135°F (57°C).
U(L,R)G2PV75H Models: Normally open, closes on vacuum increase
@ -0.96" W.C.; Opens on vacuum decrease @ -.91" W.C.
115 VAC, 60 Hz, 3.3 amps, 3300 RPM.
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Urg2pv75h76 n19 seriesUlg2pv75h76 n19 series

Table of Contents